Gait speed improvement and persistent trunk acceleration asymmetry after arthroscopic rotator cuff repair: A five-time-point exploratory study
Article History
-
Received: ,
Accepted: ,
,
Abstract
Objectives:
After arthroscopic rotator cuff repair (ARCR), unilateral upper-limb immobilization and brace removal may alter whole-body movement, whereas conventional gait measures may not fully capture postoperative movement adaptation. This exploratory study described 5-time-point changes in gait speed, step length, trunk acceleration, and bilateral mediolateral (ML) trunk asymmetry after ARCR.
Methods:
Twenty consecutive eligible patients with medium-sized rotator cuff tears (70.9 ± 8.4 years; 11 women) were assessed at 5 time points: Within 3 days before surgery (T1), postoperative day 1 (T2), immediately before brace removal at 4 weeks (T3), the first assessment after brace removal (T4), and 4 weeks thereafter (T5). Walking at self-selected speed was recorded using a single triaxial accelerometer fixed at L3. Main outcomes were gait speed, step length, trunk acceleration root-mean-square, and bilateral ML symmetry index (SI). One-way repeated-measures analysis of variance was used.
Results:
All participants completed all five assessments without missing data. Gait speed and step length were lowest at T2 and increased by T3. The ML SI peaked at T2 (median 85.1%), remained numerically elevated at T3 and T4, and decreased by T5 to a median of 26.4%.
Conclusion:
Gait speed and step length increased by the assessment immediately before brace removal, whereas ML trunk asymmetry remained numerically elevated across the brace-removal transition and decreased by 4 weeks after brace removal. A single L3-mounted accelerometer may provide adjunctive information beyond conventional spatiotemporal gait measures in postoperative musculoskeletal rehabilitation.
Keywords
How to cite this article: Kamimura A, Takayama K. Gait speed improvement and persistent trunk acceleration asymmetry after arthroscopic rotator cuff repair: A five-time-point exploratory study. J Musculoskelet Surg Res. doi: 10.25259/JMSR_316_2026
INTRODUCTION
Arthroscopic rotator cuff repair (ARCR) is commonly followed by several weeks of shoulder abduction bracing to protect the repaired tendon.[1] Although bracing targets the shoulder joint, the resulting unilateral upper-limb constraint may alter arm swing and disrupt trunk-pelvic coordination during walking, and brace removal at 4 weeks represents a distinct transition in postoperative upper-limb loading. In orthopedic surgery practice, postoperative functional recovery is typically assessed using self-reported outcome measures, pain scores, or basic gait parameters such as gait speed; however, these measures may not fully capture residual whole-body movement adaptations that persist after brace discontinuation.
Upper-limb movement is coupled with trunk and pelvic rotation, and restricting arm swing can alter gait and dynamic stability.[2,3] Studies of shoulder abduction bracing after ARCR have examined spatiotemporal parameters and gait symmetry.[4,5] Early postoperative postural stability may also be impaired.[6] A related study from our institution reported that gait and trunk-acceleration changes across brace removal were associated with falls within 30 days after discharge, with most first falls occurring within the 1st week.[7] That study focused on T3–T4 change scores and fall status rather than 5-time-point side-specific mediolateral (ML) asymmetry. Other studies have addressed stance-phase effects of unilateral shoulder disorders and activity changes during shoulder immobilization.[8,9] However, side- and direction-specific trunk acceleration across the brace-removal transition remains insufficiently characterized. Lumbar triaxial accelerometry offers a low-burden method for examining these adaptations.
Gait speed and step length are established mobility indicators. Gait-speed-normalized trunk acceleration root-mean-square (RMS) can characterize walking dynamics.[10] The bilateral ML symmetry index (SI) was used to quantify side-to-side asymmetry that might persist despite improvement in spatiotemporal gait measures. Bilateral knee-extensor strength was assessed as a contextual secondary outcome to examine whether lower-limb strength changed in parallel with gait outcomes.
We therefore conducted a 5-time-point exploratory study to describe changes in gait speed, step length, trunk acceleration, and bilateral ML trunk asymmetry from before surgery to 4 weeks after brace removal. In addition to describing postoperative changes over time, we specifically examined whether recovery of conventional spatiotemporal gait measures paralleled changes in side-specific ML trunk acceleration and bilateral asymmetry. We hypothesized that (i) gait function would be most impaired on postoperative day 1; (ii) conventional spatiotemporal measures and overall trunk acceleration RMS would improve earlier than bilateral symmetry indices; and (iii) bilateral trunk asymmetry would remain elevated across the brace-removal transition.
MATERIALS AND METHODS
Study design
This single-center prospective longitudinal observational study is reported in accordance with the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement.[11]
Consecutive patients undergoing ARCR from January to December 2025 were screened. Eligibility was prospectively restricted to patients with medium-sized rotator cuff tears managed with the standardized 4-week shoulder-abduction-brace protocol so that the brace-removal transition could be assessed at uniform postoperative time points. Eligible participants were assessed from the preoperative period (T1) to 4 weeks after brace removal (T5), with follow-up completed by February 2026. No a priori sample-size calculation was performed because this was an exploratory study.
Participants
Twenty consecutive eligible patients were included. Tear size was assessed preoperatively on magnetic resonance imaging according to the DeOrio-Cofield classification; mediumsized tears were defined as 1–3 cm.[12,13] Eligibility was prospectively restricted to medium-sized tears managed with the standardized 4-week brace protocol to standardize brace duration and the timing of T3 and T4; other tear sizes were not eligible. Patients who were unable to walk independently before surgery or had severe neurological or orthopedic disorders affecting gait were excluded. No otherwise eligible patient was excluded during the study period, and all included participants completed all five assessments without missing data. Fifteen of the 20 participants were also included in our previously published 49-patient cohort examining T3–T4 gait/trunk-acceleration changes and 30-day falls; that study used a separate ethics approval and different outcomes.[7]
Surgery
All procedures were performed arthroscopically by the same two senior shoulder surgeons. Subscapularis tears were repaired with a one-anchor single-row technique or a two- to four-anchor suture-bridge configuration according to intraoperative findings; supraspinatus and infraspinatus tears were repaired using a four-anchor suture-bridge configuration.
All participants followed the standardized medium-tear postoperative protocol and wore a shoulder abduction brace continuously for 4 weeks, including a water-resistant brace during bathing. Abduction was approximately 60° for the first 2 weeks and 30° for the next 2 weeks; the brace was removed at 4 weeks.
After brace removal, rehabilitation was performed according to the institutional protocol. Active shoulder motion progressed from supine to antigravity sitting and standing, followed by rotator cuff, elastic resistance, and table-sanding exercises as tolerated. Activities-of-daily-living guidance and exercise progression were individualized based on pain and clinical recovery.
Measurement procedures
Participants walked at a self-selected comfortable pace along a level indoor walkway. Analyses used the central 10-m segment after excluding 1-m approach and exit sections. One trial was recorded at T2 to reduce immediate postoperative burden; three trials were averaged at the other time points. Walking pain (numerical rating scale [NRS], 0–10) and bilateral isometric knee-extensor strength were measured at each time point using a belt-fixed hand-held dynamometer (μTas F-1; Anima Corporation, Tokyo, Japan). The NRS and belt-fixed dynamometry have established measurement properties, although the validity evidence for handheld dynamometry was not obtained using the identical device and protocol.[14-16]
Time points were T1, within 3 days before surgery; T2, postoperative day 1; T3, immediately before brace removal at 4 weeks; T4, the first assessment after brace removal; and T5, 4 weeks after T4 (approximately 8 weeks after surgery). These clinically defined stages were selected to track recovery across immobilization and brace removal.
Gait analysis and data processing
A triaxial accelerometer (AYUMI EYE Medical; Waseda Elderly Health Association Co., Ltd., Tokyo, Japan) was secured at L3 with an elastic belt to record trunk acceleration. RMS for the vertical (VT), anteroposterior (AP), and ML axes was normalized by gait speed squared and expressed in m-1.[10] Overall normalized RMS was the arithmetic mean of the three axes. Direction-specific peaks were calculated for upward, downward, anterior, posterior, operated-side, and non-operated-side directions. Waist-mounted accelerometry has been validated for step detection and gait-speed estimation in older populations.[17] Device-specific validation of the normalized RMS and bilateral SI used here remains limited.
A bilateral SI was derived from the operated-side and non-operated-side ML peak acceleration magnitudes, defined as SI = |Op−Non-op|/(Op+Non-op) × 200 (%). Higher values denote greater asymmetry; an SI of 0% indicates perfect bilateral symmetry. ML peak acceleration was used for the SI to characterize side-specific trunk excursion patterns that may be obscured in axis-averaged RMS values.
Outcomes
The main outcomes were gait speed (m/s), step length (cm), trunk acceleration RMS, and the bilateral ML SI. Exploratory outcomes were direction-specific trunk acceleration magnitude, walking pain (NRS), and bilateral lower-limb muscle strength (kgf; sum of right and left isometric knee extensor strength).
Statistical analysis
A one-way repeated-measures analysis of variance (ANOVA) tested the effect of time (T1–T5) for each outcome. Sphericity was assessed with Mauchly’s test, and the Greenhouse– Geisser correction was applied when the assumption was violated. Residual normality was examined because several outcomes showed non-normal residuals; Friedman tests were added as sensitivity analyses. Effect sizes are partial eta-squared (η2p). Predefined pairwise comparisons versus T2 used Wilcoxon signed-rank tests with Bonferroni adjustment. Because ML SI was skewed, it is reported as mean ± standard deviation (SD) and median (interquartile range [IQR]). Two-sided a was 0.05. Analyses used R 4.4.0 with the EZR add-on.[18]
RESULTS
Participant characteristics
Twenty patients (11 women, 9 men) with a mean age of 70.9 ± 8.4 years (range 48–83 years) were analyzed. The right shoulder was operated on in 14 patients and the left in six. All tears were classified as medium-sized [Table 1].
| Variable | Value |
|---|---|
| Age (years), mean±SD (range) | 70.9±8.4 (48–83) |
| Sex, women/men | 11/9 |
| Operated side, right/left | 14/6 |
| Tear size | All medium |
| Number of surgeons | 2 |
| Excluded by eligibility criteria | 0 |
| Patients lost to follow-up | 0 |
Values are presented as counts or as mean±standard deviation (SD)
Walking pain
Walking pain showed a significant main effect of time (F [2.33, 44.34] = 31.85, p < 0.001, η2p = 0.626). Pain peaked at T2 (mean 3.25 ± 1.48) and was significantly higher than at all other time points (all adjusted p < 0.01); by T5, the mean value had decreased to 0.55 ± 0.61 [Table 2].
| Variable | T1 | T2 | T3 | T4 | T5 | F | p-value | η2p |
|---|---|---|---|---|---|---|---|---|
| Walking pain (NRS, 0-10) | 1.00±0.00 | 3.25±1.48 | 0.85±0.49 | 1.60±1.23 | 0.55±0.61 | 31.85 | <0.001 | 0.626 |
| Lower-limb strength (kgf, R+L) | 63.3±30.1 | 63.1±30.2 | 62.8±33.5 | 62.7±33.5 | 68.9±34.6 | 4.61 | 0.018 | 0.195 |
| Gait speed (m/s) | 1.17±0.19 | 0.99±0.21 | 1.17±0.17 | 1.12±0.20 | 1.25±0.11 | 9.99 | <0.001 | 0.345 |
| Step length (cm) | 61.7±6.1 | 54.8±8.9 | 61.7±7.0 | 59.0±7.8 | 65.1±5.4 | 16.07 | <0.001 | 0.458 |
A two-sided p-value <0.05 was considered statistically significant. Values are mean±standard deviation. T1: preoperative; T2: postoperative day 1; T3: immediately before brace removal (4 weeks); T4: the first assessment after brace removal; T5: 4 weeks post-removal. Walking pain: T2 differed from all other time points (all adjusted p<0.01). Lower-limb strength: T5 >T2 (adjusted p=0.029). Gait speed and step length: T2 differed from T1, T3, T4, and T5 (all adjusted p<0.05). NRS: Numerical rating scale; kgf: Kilogram-force. Degrees of freedom were (4, 76), except where Greenhouse–Geisser correction was applied for violation of sphericity: walking pain (2.33, 44.34) and lower-limb strength (1.91, 36.34)
Gait speed
Gait speed showed a significant main effect of time (F [4,76] = 9.99, p < 0.001, η2p = 0.345). Speed was lowest at T2 (0.99 ± 0.21 m/s) and significantly higher at T1, T3, T4, and T5 (all adjusted p < 0.05 ) [Table 2]. The mean gait speed was 1.17 m/s at both T1 and T3.
Step length and trunk acceleration root-mean-square
Step length showed a significant main effect of time (F [4,76] = 16.07, p < 0.001, η2p = 0.458) [Table 2] and was significantly reduced at T2. The overall normalized trunk acceleration RMS showed a significant main effect of time (F [1.58, 29.93] = 12.90, p < 0.001, η2p = 0.404); all three axes (VT, AP, and ML) showed a significant main effect of time, with the highest mean values at T2 [Table 3].
| Direction | T1 | T2 | T3 | T4 | T5 | F | p-value | η2p |
|---|---|---|---|---|---|---|---|---|
| Overall RMS | 1.38±0.20 | 1.97±0.76 | 1.42±0.28 | 1.48±0.24 | 1.29±0.22 | 12.90 | <0.001 | 0.404 |
| AP | 1.42±0.42 | 2.39±1.46 | 1.50±0.60 | 1.52±0.38 | 1.22±0.29 | 8.50 | 0.002 | 0.309 |
| ML | 0.92±0.25 | 1.39±0.82 | 0.93±0.37 | 1.06±0.41 | 0.89±0.26 | 7.14 | 0.003 | 0.273 |
| VT | 1.82±0.22 | 2.13±0.38 | 1.82±0.25 | 1.86±0.29 | 1.76±0.34 | 8.59 | <0.001 | 0.311 |
A two-sided p-value <0.05 was considered statistically significant. Values are mean±standard deviation. All three axes showed a significant main effect of time, with the highest mean values at T2. Degrees of freedom were Greenhouse-Geisser–corrected for all rows: Overall (1.58, 29.93), AP (1.55, 29.52), ML (1.79, 34.00), and vertical (2.72, 51.77). T1: Within 3 days before surgery; T2: Postoperative day 1; T3: Immediately before brace removal at 4 weeks postoperatively; T4: The first assessment after brace removal; T5: 4 weeks after T4. RMS: Root-mean-square, AP: Anteroposterior, ML: Mediolateral, VT: Vertical
Direction-specific trunk acceleration and bilateral asymmetry
Direction-specific peak acceleration magnitudes showed significant main effects of time in the upward (F [4,76] = 4.16, p = 0.004, η2p = 0.180), downward (F [4,76] = 4.76, p = 0.002, η2p = 0.200), and anterior (F [4,76] = 4.80, p = 0.002, η2p = 0.202) directions, but not in the posterior direction (p = 0.22) [Table 4].
| Variable | T1 | T2 | T3 | T4 | T5 | F | p-value | η2p |
|---|---|---|---|---|---|---|---|---|
| Upward (g) | 0.52±0.22 | 0.40±0.18 | 0.55±0.26 | 0.47±0.20 | 0.58±0.21 | 4.16 | 0.004 | 0.180 |
| Downward (g) | 0.31±0.12 | 0.22±0.16 | 0.32±0.17 | 0.32±0.16 | 0.36±0.14 | 4.76 | 0.002 | 0.200 |
| Anterior (g) | 0.24±0.10 | 0.15±0.12 | 0.23±0.12 | 0.23±0.12 | 0.26±0.11 | 4.80 | 0.002 | 0.202 |
| Posterior (g) | 0.24±0.13 | 0.34±0.24 | 0.27±0.16 | 0.25±0.14 | 0.27±0.09 | 1.56 | 0.22 | 0.076 |
| Non-operated ML (g) | 0.190±0.070 | 0.092±0.051 | 0.126±0.060 | 0.160±0.076 | 0.206±0.062 | 14.20 | <0.001 | 0.428 |
| Operated ML (g) | 0.183±0.081 | 0.187±0.100 | 0.196±0.073 | 0.214±0.118 | 0.188±0.054 | 0.58 | 0.68 | 0.030 |
| SI, mean±SD (%) | 33.0±16.6 | 82.8±53.8 | 60.4±41.7 | 50.3±38.2 | 28.9±22.6 | 8.18 | <0.001 | 0.301 |
| SI, median (%) | 31.2 | 85.1 | 47.1 | 41.3 | 26.4 | — | — | — |
| SI, IQR (%) | 20.1–47.6 | 46.5–109.2 | 27.7–87.4 | 20.3–57.2 | 11.6–37.8 | — | — | — |
A two-sided p-value <0.05 was considered statistically significant. Values are mean±standard deviation (SD) unless otherwise stated. g: Standard gravitational unit, ML: Mediolateral, SI: Symmetry index = |Op−Non-op|/(Op+Non-op) × 200 (%); higher values indicate greater asymmetry. For the SI rows, F statistics, p-values, and η-2p apply to the SI mean±SD row; median and interquartile range (IQR) are descriptive. T1: Within 3 days before surgery; T2: Postoperative day 1; T3: Immediately before brace removal at 4 weeks postoperatively; T4: The first assessment after brace removal; T5: 4 weeks after T4. Degrees of freedom were (4, 76), except for posterior peak acceleration, which was Greenhouse-Geisser–corrected (2.32, 44.07)
A notable dissociation was observed in the ML direction. Non-operated-side ML peak acceleration showed a substantial, ordered effect of time (F [4,76] = 14.20, p < 0.001, η2p = 0.428), falling sharply from 0.190 ± 0.070 g at T1 to 0.092 ± 0.051 g at T2 and increasing progressively to 0.206 ± 0.062 g by T5. In contrast, operated-side ML peak acceleration showed no main effect of time (F [4,76] = 0.58, p = 0.68, η2p = 0.030); values fluctuated within a narrow band of 0.18–0.21 g across the entire postoperative course [Table 4].
SI showed a significant main effect of time (F [4,76] = 8.18, p < 0.001, η2p = 0.301) [Table 4], peaked at T2 (median 85.1%, IQR 46.5 -109.2%), and decreased by T5 to a median of 26.4% (IQR 11.6 -37.8%). The asymmetry remained numerically elevated at T3 and T4 despite increased gait speed.
Lower-limb muscle strength
Bilateral lower-limb extensor strength showed a small but significant main effect of time (F [1.91, 36.34] = 4.61, p = 0.018, η2p = 0.195) [Table 2], driven by a modest increase at T5 relative to T2 (adjusted p = 0.029). No other pairwise difference was significant. Across all outcomes, the non-parametric Friedman sensitivity analyses yielded the same pattern of significant and non-significant main effects of time as the repeated-measures ANOVA.
These results suggest that spatiotemporal measures and bilateral trunk symmetry may follow distinct, phase-specific trajectories after ARCR [Figure 1].

DISCUSSION
In this 5-time-point longitudinal study, we observed three principal findings: (i) Walking pain, gait speed, step length, and trunk acceleration RMS deteriorated maximally on postoperative day 1 (T2) and improved by T3, the assessment immediately before brace removal; (ii) operated-side ML trunk acceleration showed no significant main effect of time, whereas the non-operated side showed a marked reduction at T2 followed by a gradual increase; and (iii) the bilateral SI exposed an asymmetry that remained elevated across the brace-removal transition and decreased by 4 weeks thereafter.
The marked deterioration at T2 may reflect the combined effects of acute postoperative pain and abrupt unilateral upper-limb constraint. Musculoskeletal pain in older adults has been associated with slower gait speed and greater gait variability.[19] Restriction of arm swing disrupts trunk-pelvic coordination and reduces dynamic stability.[3] Within an internal-model framework, such postoperative perturbations could plausibly increase sensory prediction error and reduce control precision.[20]
A clinically relevant observation of the present study was the dissociation between improvement in conventional spatiotemporal gait measures and recovery of bilateral ML trunk symmetry. Gait speed and step length had increased by T3, whereas the ML SI remained numerically elevated at T3 and T4. This finding suggests that improvement in gait speed should not necessarily be interpreted as complete normalization of whole-body movement adaptation after ARCR. A related study from our institution identified the brace-removal period as clinically relevant for early falls, but it did not evaluate the present SI and therefore does not establish the prognostic significance of ML asymmetry.[7] Previous studies have examined basic spatiotemporal gait parameters and wearable-sensor-derived gait symmetry after ARCR or shoulder immobilization.[4,5] In this exploratory context, side-specific trunk acceleration may therefore provide information complementary to conventional gait speed and step-length assessment.
An important exploratory observation is the dissociation between the operated and non-operated ML channels. The operated-side signal showed no statistically significant main effect of time, while the non-operated side showed a marked reduction at T2 followed by a gradual increase. The SI integrating these two channels was therefore sensitive to changes not apparent from gait speed, step length, the operated-side channel alone, or trunk acceleration RMS. This pattern may indicate a phase-specific compensatory strategy rather than immediate restoration of symmetric ML trunk movement. Accordingly, restoration of bilateral ML symmetry may lag behind improvement in spatiotemporal performance. Force plate-based postural balance assessments have reported impaired postural stability in the early postoperative period after ARCR.[6] The present study characterized gait-related asymmetry in trunk acceleration across five longitudinal time points spanning the brace-removal transition, suggesting a distinct and complementary dimension of postoperative movement adaptation.
These exploratory findings suggest that a single L3-mounted accelerometer may provide information that complements conventional gait speed and step-length assessments during postoperative rehabilitation, particularly around the transition from brace use to brace removal. However, the clinical significance of the observed asymmetry remains uncertain. No clinically meaningful threshold has been established for the SI used in this study. Falls were not an outcome of the present study and were not analyzed in relation to the SI. Therefore, persistent ML asymmetry should not be interpreted as a demonstrated marker of fall risk or delayed clinical recovery. Further adequately powered prospective studies are needed to determine whether this asymmetry is associated with patient-relevant outcomes.
The absence of parallel deterioration in bilateral knee extensor strength suggests that generalized lower-limb weakness alone is unlikely to explain the SI pattern. However, this inference remains exploratory because lower-limb strength was represented only by the sum of isometric knee extensor force and was not normalized to body mass.
When interpreting the magnitude of the gait-speed changes, several general reference values provide context. Perera et al. proposed approximately 0.05 m/s as a small meaningful change and approximately 0.10 m/s as a substantial change in gait speed.[21] Bohannon and Glenney concluded that changes of 0.10–0.20 m/s may be important across multiple patient groups.[22] The observed mean changes of 0.18 m/s from T1 to T2 and from T2 to T3 exceeded the reference values proposed by Perera et al. and fell within the range reported by Bohannon and Glenney.[21,22] However, these thresholds were derived from other populations, are not specific to patients undergoing ARCR, and do not establish clinically important change at the individual-patient level. No minimal clinically important difference thresholds were applied to the normalized trunk-acceleration RMS or the SI, because no directly applicable thresholds were identified in the literature reviewed for this study; these outcomes were therefore interpreted using effect sizes and within-subject trajectories.
Several limitations should be acknowledged. The single-center design with 20 patients limits generalizability, and the study was deliberately exploratory with no a priori sample size calculation. The contributions of pain and mechanical immobilization could not be separated. Upper-limb kinematics and electromyographic activity were not recorded, limiting mechanistic inference. Shoulder functional outcome scores (e.g., American Shoulder and Elbow Surgeons, Constant score) were not included in this study and would have provided additional clinical context. Additional clinical descriptors that may influence gait – including body mass index, dominant hand, symptom duration, comorbidities (e.g., diabetes, low back pain) – were not systematically collected and should be incorporated in future cohorts. Because only one gait trial was recorded at T2 to reduce immediate postoperative burden, whereas three trials were averaged at the other time points, measurement variability at T2 may have differed from that at the remaining assessments. This methodological difference should be considered when interpreting the magnitude of early postoperative changes. The absence of a control group precludes causal inference. Because ML asymmetry was already observed preoperatively in some participants, this study cannot determine whether postoperative asymmetry reflected surgical recovery, brace immobilization, or pre-existing gait characteristics. Generalizability is further limited by the single surgical center and the deliberate restriction to medium-sized tears receiving a 4-week brace protocol. Adequately powered, controlled, and multi-center studies are warranted to confirm these observations. Fifteen of the 20 participants were also included in a related published cohort from our institution that addressed gait changes following brace removal and falls.[7]
Reporting guideline
This observational study was reported in accordance with the STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) statement. A completed STROBE checklist is provided as a Supplementary File 1.
CONCLUSION
In this exploratory 5-time-point study of 20 patients after ARCR, most of whom were older adults, gait speed and step length increased by the assessment immediately before brace removal, whereas bilateral ML trunk acceleration asymmetry remained numerically elevated across brace removal and decreased by 4 weeks after brace removal. These findings suggest that conventional spatiotemporal measures may not fully capture postoperative whole-body movement adaptation in patients undergoing orthopedic shoulder surgery. Complete 5-time-point data acquisition without missing data suggests that repeated single-accelerometer assessment may be a low-burden adjunctive measure in postoperative rehabilitation, although feasibility outcomes should be pre-specified in future studies. Further controlled studies are needed to confirm these observations.
Recommendations
Single L3-mounted accelerometer assessment may be considered as an adjunct to conventional gait speed and step length assessment during postoperative rehabilitation after ARCR, especially around brace removal. Future studies should prospectively evaluate whether ML trunk asymmetry predicts clinically relevant outcomes such as falls, mobility limitation, or delayed functional recovery.
Acknowledgment:
The authors thank the rehabilitation and orthopedic staff at the study institution for their assistance with data collection.
Author contributions:
AK: Conceived and designed the study, conducted research, collected and organized data, analyzed and interpreted data, and wrote the initial and final draft of the article; KT: Provided research materials, supervised the study, and critically reviewed the manuscript. All authors have critically reviewed and approved the final draft and are responsible for the manuscript’s content and similarity index.
Ethical approval:
The study was approved by the Ethics Committee of Mabi Memorial Hospital, approval number 2025-001, dated 14 January 2025.
Declaration of patient consent:
The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given consent for clinical information to be reported in the journal. The patient understands that the patient’s names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.
Use of artificial intelligence (AI)-assisted technology for manuscript preparation:
The authors confirm that there was use of AI-assisted technology. ChatGPT (OpenAI) and Claude (Anthropic) were used to assist with language editing, manuscript organization, preparation of author-directed revisions, and identification of candidate references during manuscript revision. The tools were not used for study design, data collection, or independent scientific decision-making. All statistical analyses, interpretation of findings, selection and verification of final references, and approval of the manuscript content were performed by the authors. The authors critically reviewed and verified all AI-assisted content and take full responsibility for the scientific content of the manuscript.
Conflict of interest:
There are no conflicting relationships or activities.
Financial support and sponsorship: This study did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
References
- Use of a shoulder abduction brace after arthroscopic rotator cuff repair: A study on gait performance and falls. Prosthet Orthot Int. 2018;42:136-43.
- [CrossRef] [PubMed] [Google Scholar]
- Influence of arm potision on gait parameters in healthy young adults. Jpn J Health Promot Phys Ther. 2013;3:119-22.
- [CrossRef] [Google Scholar]
- The effects of arm swing on human gait stability. J Exp Biol. 2010;213:3945-52.
- [CrossRef] [PubMed] [Google Scholar]
- Does immobilization of the shoulder in different positions affect gait? Gait Posture. 2022;91:254-9.
- [CrossRef] [PubMed] [Google Scholar]
- Shoulder brace has no detrimental effect on basic spatio-temporal gait parameters and functional mobility after arthroscopic rotator cuff repair. Gait Posture. 2024;107:207-11.
- [CrossRef] [PubMed] [Google Scholar]
- Postural balance impairment following arthroscopic rotator cuff repair in the early postoperative period: A prospective cohort study. BMC Sports Sci Med Rehabil. 2025;17:1.
- [CrossRef] [PubMed] [Google Scholar]
- Brace-removal transition, gait changes, and early falls after arthroscopic rotator cuff repair. Arch ISPRM. 2026;1:171-9.
- [CrossRef] [Google Scholar]
- Effect of unilateral shoulder disorder on the stance phase of human gait. ScientificWorldJournal. 2022;2022:8205879.
- [CrossRef] [PubMed] [Google Scholar]
- How shoulder immobilization influences daily physical activity-an accelerometer based preliminary study. BMC Musculoskelet Disord. 2020;21:126.
- [CrossRef] [PubMed] [Google Scholar]
- Minimal detectable change in inertial measurement unit-based trunk acceleration indices during gait in inpatients with subacute stroke. Sci Rep. 2023;13:19262.
- [CrossRef] [PubMed] [Google Scholar]
- The strengthening the reporting of observational studies in epidemiology (STROBE) statement: Guidelines for reporting observational studies. Lancet. 2007;370:1453-7.
- [CrossRef] [PubMed] [Google Scholar]
- Results of a second attempt at surgical repair of a failed initial rotator-cuff repair. J Bone Joint Surg Am. 1984;66:563-7.
- [CrossRef] [Google Scholar]
- Exploring multifactorial influences on rotator cuff tear sizes: A comprehensive analysis. J Musculoskelet Surg Res. 2026;10:415-20.
- [CrossRef] [Google Scholar]
- Validity of four pain intensity rating scales. Pain. 2011;152:2399-404.
- [CrossRef] [PubMed] [Google Scholar]
- Test-retest reliability of isometric leg muscle strength measurements made using a hand-held dynamometer restrained by a belt: Comparisons during and between sessions. J Phys Ther Sci. 2009;21:239-43.
- [CrossRef] [Google Scholar]
- Relative validity and reliability of isometric lower extremity strength assessment in older adults by using a handheld dynamometer. Sports Health. 2022;14:899-905.
- [CrossRef] [PubMed] [Google Scholar]
- Validity of accelerometry in step detection and gait speed measurement in orthogeriatric patients. PLoS One. 2019;14:e0221732.
- [CrossRef] [PubMed] [Google Scholar]
- Investigation of the freely available easy-to-use software 'EZR' for medical statistics. Bone Marrow Transplant. 2013;48:452-8.
- [CrossRef] [PubMed] [Google Scholar]
- The severity and number of musculoskeletal pain associated with gait in community-dwelling elderly individuals. Gait Posture. 2017;54:242-7.
- [CrossRef] [PubMed] [Google Scholar]
- Error correction, sensory prediction, and adaptation in motor control. Annu Rev Neurosci. 2010;33:89-108.
- [CrossRef] [PubMed] [Google Scholar]
- Meaningful change and responsiveness in common physical performance measures in older adults. J Am Geriatr Soc. 2006;54:743-9.
- [CrossRef] [PubMed] [Google Scholar]
- Minimal clinically important difference for change in comfortable gait speed of adults with pathology: A systematic review. J Eval Clin Pract. 2014;20:295-300.
- [CrossRef] [PubMed] [Google Scholar]