Among the many hazards that exist in the operating room, the radiation hazard to patients, surgeons, and operating room staff is a great concern. X-ray is an ionizing radiation that causes many pathologies, the most harmful being the development of malignant tumors. Although these are established facts, unfortunately, many orthopedic surgeons and operating room staff still do not take enough precautions to minimize radiation hazards to themselves and to patients they care for.
In a survey of cancer incidence, among 316 hospital employees over a period of 24 years, Mastrangelo et al.[1] determined that orthopedic surgeons had a significantly higher risk for cancer development (P < 0.002) compared to exposed other than orthopedics and unexposed workers.
The International Commission on Radiological Protection produced specific guidelines regarding radiation dosage for those exposed in occupational settings.[2]
In the Journal's previous issue (Vol. 5, Issue 1, January–March 2021), two papers discussed radiation hazards. One discussed how scoliosis patients are exposed to increased cumulative radiation doses during management and drew our attention to look carefully at methods to reduce radiation exposure to patients.[3] This is more important in the pediatric population as radiation may have more harmful long-term effects.[4],[5] Indeed, we need to carefully look at the benefits and risks involved when requesting X-rays for patients in every orthopedic visit and should be very selective on how many images and views are needed initially, intraoperatively, and during follow-ups. In general, the principle of ALARA “As Low As Reasonably Achievable” should always be kept in mind while requesting or using radiation.[6] On initial assessment after trauma, if there are no swelling, no tenderness, and a good range of motion of the joint, an X-ray is not clinically recommended. A comparative X-ray of the noninjured side is not recommended anymore as this was proven not to be of benefit in the vast majority of cases.[7],[8] If comparison views are felt necessary, normal X-rays in various age groups are available on the net to compare. Another example is reducing the number of views requested for the injured part, e.g., an anteroposterior (AP) view is sufficient for a suspected neck femur fracture and for clinically obvious diaphyseal fractures of long bones with a clinically evident deformity that requires reduction under anesthesia or surgical fixation. As internal oblique view for the lateral humeral condyle in children is better in diagnosing and assessing the type and displacement,[9] requesting a single internal oblique view is better than requesting AP and lateral views of the elbow followed by the oblique view. During surgical procedures, radiation from the machines and the number of images could be reduced by ensuring and maintaining good communication with the X-ray technician during procedures.[10] The amount of radiation could be well reduced by using pulsed and low-dose mode fluoroscopy.[11] Pulsed fluoroscopy uses 1–6 images per second with much lower radiation exposure compared to continuous imaging, which uses 25–30 images per second.[12] The use of laser aiming guides, body part marking, and sticky tape on the floor to mark the C-arm position during surgery all help preventing off-center x-rays and thus reduce the number of images during surgery.[13] Using collimation to reduce the size of the aperture and voiding magnification both play a role in reducing the radiation dose.[11] The source of the radiation (the X-ray tube) should be kept as far from the patient as possible during the use of intraoperative C-arms.[14] These measures reduce the direct radiation to the patient and the scatter radiation to the staff. Patients' sensitive organs should be protected, especially when they are close to parts imaged. However, care should be taken to place protective shields properly, avoiding obliterating important areas to be viewed on the films, which would lead to repeated exposure. On follow-ups, a clinical judgment could replace unnecessary X-rays requests for many fractures; examples are fractures of the clavicle, metatarsals, metacarpals, and nondisplaced green-stick fractures.[15],[16],[17]
The other paper in the Journal's previous issue showed that the background knowledge and methods of reducing radiation during the use of C-arms in the operating room were indeed poor among doctors working in orthopedics. This clearly shows the importance of establishing mini-courses on radiation safety in the operating room.[18]
Among the measures that should be taken to minimize radiation exposure to staff and surgeons is shielding by using protective gear.[19] A lead-equivalent thickness of 0.5 mm attenuates over 95% of scattered X-rays that strike it.[20] Thyroid tissue is known to be susceptible to ionizing radiation and cancer; unfortunately, thyroid protection is frequently omitted by many orthopedic surgeons and staff during surgery.
Combining shielding with the reduction of exposure measures mentioned above results in a 97.3% reduction in effective dose to all operative room staff.[21]
Other important and effective simple measures include proper configuration of the C-arms with the tube away from the surgeon in the lateral view, which reduces the radiation to the surgeon 25-fold[22] and with the tube below the table in an AP view[23] and staying at the furthest distance possible. Combined with proper shielding, staying at the right distance reduces scattered radiation to 0.1% and 0.025% of the primary radiation at a distance of 3 and 6 feet, respectively.[24] With the X-ray tube below the table, dosimeters at a distance of 6 feet reported no radiation exposure.[13] Literature suggests that, at a distance of 2 M or more away from the radiation source (tube for direct radiation and patient for scatter radiation), the amount of radiation is almost none, even without protective gear.[25]
Cumulative radiation measuring badges (dosimeters) are highly recommended to measure and monitor the radiation exposure of surgeons and staff.[26]
We should all take radiation exposure seriously and continue reminding colleagues of the importance of taking proper safety measures for the patients, staff, and ourselves while using C-arm machines in the operating room.
Financial support and sponsorship
This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
Conflicts of interest
There are no conflicts of interest.
1. | Mastrangelo G, Fedeli U, Fadda E, Giovanazzi A, Scoizzato L, Saia B. Increased cancer risk among surgeons in an orthopaedic hospital. Occup Med (Lond) 2005;55:498-500. [Google Scholar] |
2. | The 2007 Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Vol. 37. Elsevier: Ann ICRP; 2007;37:1-332. doi: 10.1016/j.icrp.2007.10.003. PMID: 18082557. [Google Scholar] |
3. | Konbaz FM, Alhandi AA, Almohini IA, Almubarak AK, Alamri N, Ghazal HS. Evaluation of radiation exposure from Xray imaging among scoliotic patients at a tertiary care hospital. J Musculoskelet Surg Res 2021;5:41-5. [Google Scholar] |
4. | United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) Sources, Effects and Risks of Ionizing Radiation: United Nations Scientific Committee on the Effects of Atomic Radiation: UNSCEAR 2013 Report to the General Assembly with Scientific Annexes. Vienna, Austria: UNSCEAR; 2013. [Google Scholar] |
5. | Kutanzi KR, Lumen A, Koturbash I, Miousse IR. Pediatric exposures to ionizing radiation: carcinogenic considerations. Int J Environ Res Public Health 2016;13:1057. [Google Scholar] |
6. | Hendee WR, Edwards FM. ALARA and an integrated approach to radiation protection. Semin Nucl Med 1986;16:142-50. [Google Scholar] |
7. | Kissoon N, Galpin R, Gayle M, Chacon D, Brown T. Evaluation of the role of comparison radiographs in the diagnosis of traumatic elbow injuries. J Pediatr Orthop 1995;15:449-53. [Google Scholar] |
8. | Chacon D, Kissoon N, Brown T, Galpin R. Use of comparison radiographs in the diagnosis of traumatic injuries of the elbow. Ann Emerg Med 1992;21:895-9. [Google Scholar] |
9. | Song KS, Kang CH, Min BW, Bae KC, Cho CH. Internal oblique radiographs for diagnosis of nondisplaced or minimally displaced lateral condylar fractures of the humerus in children. J Bone Joint Surg Am 2007;89:58-63. [Google Scholar] |
10. | Yeo CH, Gordon R, Nusem I. Improving operating theatre communication between the orthopaedics surgeon and radiographer. ANZ J Surg 2014;84:316-9. [Google Scholar] |
11. | Goodman BS, Carnel CT, Mallempati S, Agarwal P. Reduction in average fluoroscopic exposure times for interventional spinal procedures through the use of pulsed and low-dose image settings. Am J Phys Med Rehabil 2011;90:908-12. [Google Scholar] |
12. | Srinivasan D, Than KD, Wang AC, La Marca F, Wang PI, Schermerhorn TC, et al. Radiation safety and spine surgery: Systematic review of exposure limits and methods to minimize radiation exposure. World Neurosurg 2014;82:1337-43. [Google Scholar] |
13. | Shuler FD, Daigre JL, Pham D, Kish VL. Laser targeting with C-arm fluoroscopy: Effect on image acquisition and radiation exposure. J Orthop Trauma 2013;27:e97-102. [Google Scholar] |
14. | Kaplan DJ, Patel JN, Liporace FA, Yoon RS. Intraoperative radiation safety in orthopaedics: A review of the ALARA (As low as reasonably achievable) principle. Patient Saf Surg 2016;10:27. [Google Scholar] |
15. | Brown Z, Perry M, Wozniak AW, Cappello T. Decreasing radiation exposure in pediatric clavicle and metatarsal fractures: A QI initiative. J Pediatr Orthop 2021;41:177-81. [Google Scholar] |
16. | Ling SJ, Cleary AJ. Are Unnecessary Serial Radiographs Being Ordered in Children with Distal Radius Buckle Fractures? Radiol Res Pract 2018;2018:5143639. [Google Scholar] |
17. | Ting BL, Kalish LA, Waters PM, Bae DS. Reducing Cost and Radiation Exposure During the Treatment of Pediatric Greenstick Fractures of the Forearm. J Pediatr Orthop 2016;36:816-20. [Google Scholar] |
18. | Bukhary HA, Aldosari AM, Althagafi AS. Assessment of knowledge and awareness regarding radiation safety and fluoroscopy use among orthopedic surgeons in Saudi Arabia. J Musculoskelet Surg Res 2021;5:35-40. [Google Scholar] |
19. | Narain AS, Hijji FY, Yom KH, Kudaravalli KT, Haws BE, Singh K. Radiation exposure and reduction in the operating room: Perspectives and future directions in spine surgery. World J Orthop 2017;8:524-30. [Google Scholar] |
20. | Bahari S, Morris S, Broe D, Taylor C, Lenehan B, McElwain J. Radiation exposure of the hands and thyroid gland during percutaneous wiring of wrist and hand procedures. Acta Orthop Belg 2006;72:194-8. [Google Scholar] |
21. | Plastaras C, Appasamy M, Sayeed Y, McLaughlin C, Charles J, Joshi A, et al. Fluoroscopy procedure and equipment changes to reduce staff radiation exposure in the interventional spine suite. Pain Physician 2013;16:E731-8. [Google Scholar] |
22. | Rampersaud YR, Foley KT, Shen AC, Williams S, Solomito M. Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion. Spine (Phila Pa 1976) 2000;25:2637-45. [Google Scholar] |
23. | Koukorava C, Carinou E, Ferrari P, Krim S, Struelens L. Study of the parameters affecting operator doses in interventional radiology using Monte Carlo simulations. Radiation Measurements 2011;46:1216-22, SSN 1350-4487. [Google Scholar] |
24. | Singer G. Occupational radiation exposure to the surgeon. J Am Acad Orthop Surg 2005;13:69-76. [Google Scholar] |
25. | Alonso JA, Shaw DL, Maxwell A, McGill GP, Hart GC. Scattered radiation during fixation of hip fractures. Is distance alone enough protection? J Bone Joint Surg Br 2001;83:815-8. [Google Scholar] |
26. | Abaza A. New trend in radiation dosimeters. Am J Modern Physics 2018;7:21-30. [Google Scholar] |
Fulltext Views
1,797
PDF downloads
524