Translate this page into:
The accuracy of intraoperative O-arm imaging in assessing thoracolumbar pedicle screw placement
*Corresponding author: Ivo I. Kehayov, MD., PhD. Department of Neurosurgery, Faculty of Medicine, Medical University of Plovdiv, Plovdiv, Bulgaria. dr.kehayov@gmail.com
-
Received: ,
Accepted: ,
How to cite this article: Kehayov II, Kitov BD. The accuracy of intraoperative O-arm imaging in assessing thoracolumbar pedicle screw placement. J Musculoskelet Surg Res. doi: 10.25259/JMSR_44_2025
Dear Editor,
We have read with great interest the article by Aguilar-Chavez et al. that was published in your respected journal. This paper reconfirms the great advantages of intraoperative computed tomography (CT)-based spinal navigational systems that allow for higher accuracy and precision of pedicle screw placement in the thoracic and lumbar spine, thus, improving clinical outcomes and providing better quality of life for the treated patients.[1] The achieved accuracy of 95.42% by Aguilar-Chavez et al., according to the classification of Zdichavsky et al., is similar to that reported by Lu et al., who reviewed the accuracy of robotic-assisted pedicle screw placement.[1-3]
The undisputed advantages of intraoperative CT-based spinal navigational systems include lower irradiation dose for the surgical staff, which can be entirely avoided if the team leaves the operating room during scanning, the opportunity to preplan the procedure and choose the optimal screw size and trajectory, and, last but not least, the option for simultaneous intraoperative correction of misplaced screws, thus reducing the rate of revision surgeries.
In their meta-analysis, Cui et al. also report high accuracy of pedicle screw placement by means of robotic assistance leading to shorter hospital stays, but the data regarding intraoperative blood loss and complication rate in comparison to conventional techniques are somehow contradictory.[4]
In our opinion, the article by Aguilar-Chavez et al. could be even more informative for your audience if the authors had shared more data regarding the use of navigation in the setting of different spinal pathologies and other perioperative variables such as mean operative time, blood loss, and patient exposure to irradiation.[1]
Our personal belief after the placement of 1280 navigated pedicle screws by O-arm for a variety of pathologies is that some variables, such as patient irradiation exposure and intraoperative blood loss, can be reduced through optimization of imaging acquisition protocols and surgical techniques.
Author’s contributions
IIK: Conceived and designed the paper, wrote the first and final draft of the manuscript and performed English revision. BDK: Collected the literature data, provided research material, and took part in the concept of the manuscript. Both authors have critically reviewed and approved the final draft and are responsible for the manuscript’s content and similarity index.
Use of artificial intelligence (AI)-assisted technology for manuscript preparation
The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript, and no images were manipulated using AI.
Conflicts of interest
There are no conflicting relationships or activities.
References
- The accuracy of intraoperative O-arm imaging in assessing thoracolumbar pedicle screws placement. J Musculoskelet Surg Res. 2024;8:227-31.
- [CrossRef] [Google Scholar]
- Accuracy of pedicle screw placement in thoracic spine fractures-Part II: A retrospective analysis of 278 pedicle screws using computed tomographic scans. Eur J Trauma. 2004;30:2417.
- [CrossRef] [Google Scholar]
- Robotic-assisted surgery for adult spinal deformity. A systematic review. Brain Spine. 2024;4:102904.
- [CrossRef] [PubMed] [Google Scholar]
- Accuracy and postoperative assessment of robot-assisted placement of pedicle screws during scoliosis surgery compared with conventional freehand technique: A systematic review and meta-analysis. J Orthop Surg Res. 2024;19:365.
- [CrossRef] [PubMed] [Google Scholar]